{"id":232,"date":"2026-10-16T10:02:23","date_gmt":"2026-10-16T02:02:23","guid":{"rendered":"http:\/\/packagingleaktester.com\/?page_id=232"},"modified":"2026-10-16T10:02:45","modified_gmt":"2026-10-16T02:02:45","slug":"leak-tester-aio-59d","status":"publish","type":"page","link":"https:\/\/packagingleaktester.com\/index.php\/leak-tester-aio-59d\/","title":{"rendered":"Leak Tester AIO-59D"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center has-body-font-family\"><strong>Leak Tester <strong>AIO-59D<\/strong><\/strong><\/h2>\n\n\n\n<p class=\"has-large-font-size wp-block-paragraph\"><strong>1\u3001Product Overview<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Leak Tester <strong>AIO-59D<\/strong><\/strong> is purpose-built for vacuum leak and seal-integrity testing \u2014 as well as microbial ingress testing \u2014 of a wide range of packaging: pharmaceutical glass bottles, vials, plastic solid bottles, blister packs, aluminum-plastic sachets, syringes, pipettes, vacuum bags, cans, milk-powder bags, foil bags, eye-drop bottles, medical device packaging, liquid bags, jelly cups, caps, cosmetic bottles and daily-chemistry packaging.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1003\" height=\"1024\" src=\"http:\/\/packagingleaktester.com\/wp-content\/uploads\/2026\/10\/Leak-Tester03-1003x1024.png\" alt=\"\" class=\"wp-image-80\" style=\"aspect-ratio:0.9795112317946186;width:287px;height:auto\" srcset=\"https:\/\/packagingleaktester.com\/wp-content\/uploads\/2026\/10\/Leak-Tester03-1003x1024.png 1003w, https:\/\/packagingleaktester.com\/wp-content\/uploads\/2026\/10\/Leak-Tester03-294x300.png 294w, https:\/\/packagingleaktester.com\/wp-content\/uploads\/2026\/10\/Leak-Tester03-768x784.png 768w, https:\/\/packagingleaktester.com\/wp-content\/uploads\/2026\/10\/Leak-Tester03.png 1280w\" sizes=\"auto, (max-width: 1003px) 100vw, 1003px\" \/><\/figure>\n\n\n\n<p class=\"has-large-font-size wp-block-paragraph\"><strong>2\u3001Application Fields<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Application Fields \u2014 Widely adopted by pharmaceutical manufacturers, pharmaceutical packaging producers, drug inspection centers, medical device companies, food enterprises and cosmetics companies for professional seal-integrity inspection.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"897\" src=\"http:\/\/packagingleaktester.com\/wp-content\/uploads\/2026\/10\/Application-Fields.jpg\" alt=\"\" class=\"wp-image-216\" srcset=\"https:\/\/packagingleaktester.com\/wp-content\/uploads\/2026\/10\/Application-Fields.jpg 800w, https:\/\/packagingleaktester.com\/wp-content\/uploads\/2026\/10\/Application-Fields-268x300.jpg 268w, https:\/\/packagingleaktester.com\/wp-content\/uploads\/2026\/10\/Application-Fields-768x861.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p class=\"has-large-font-size wp-block-paragraph\"><strong>3\u3001Testing Principle<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">By evacuating the vacuum chamber, a pressure differential is created between the inside and outside of the sample. For a sample immersed in water, any gas escaping from it is observed; alternatively, the sample&#8217;s expansion and the recovery of its original shape after the vacuum is released are observed. Either way, the seal performance of the sample is judged accurately.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Complies with GB\/T 15171, ASTM D3078 and other standards.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"283\" height=\"300\" src=\"http:\/\/packagingleaktester.com\/wp-content\/uploads\/2026\/10\/Principle-283x300.png\" alt=\"\" class=\"wp-image-214\" srcset=\"https:\/\/packagingleaktester.com\/wp-content\/uploads\/2026\/10\/Principle-283x300.png 283w, https:\/\/packagingleaktester.com\/wp-content\/uploads\/2026\/10\/Principle.png 600w\" sizes=\"auto, (max-width: 283px) 100vw, 283px\" \/><\/figure>\n\n\n\n<p class=\"has-large-font-size wp-block-paragraph\"><strong>4\u3001Key Features<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2605 7-inch touch screen control for easier operation; curve display makes data results more intuitive<br>\u2605 Freely switch between Chinese and English operating systems<br>\u2605 One-click operation: automatic vacuum adjustment, automatic test termination, automatic pressure relief<br>\u2605 Multiple working modes, supporting multi-stage constant pressure testing and simple &amp; convenient detection<br>\u2605 Multiple unit options: KPa, MPa, Bar, PSI<br>\u2605 The vacuum chamber is made of highly transparent acrylic, sturdy and durable<br>\u2605 Automatic constant pressure air replenishment to ensure the test proceeds under the preset vacuum<br>\u2605 Adopts high-precision vacuum components with stable performance and long service life<br>\u2605 Built-in storage function, capable of saving up to 500 historical data records<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2605 <strong>Audit Trail<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Automatically records all operations and events for full traceability of test data. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2605 <strong>User Access Control<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Multi-level user permission management prevents unauthorized operation and parameter changes. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2605 <strong>Built-in Vacuum Pump<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Integrated vacuum pump simplifies equipment layout and delivers stable vacuum for testing.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"370\" src=\"http:\/\/packagingleaktester.com\/wp-content\/uploads\/2026\/10\/\u7279\u70b9-1024x370.jpg\" alt=\"\" class=\"wp-image-230\" style=\"aspect-ratio:2.767857142857143;width:488px;height:auto\" srcset=\"https:\/\/packagingleaktester.com\/wp-content\/uploads\/2026\/10\/\u7279\u70b9-1024x370.jpg 1024w, https:\/\/packagingleaktester.com\/wp-content\/uploads\/2026\/10\/\u7279\u70b9-300x108.jpg 300w, https:\/\/packagingleaktester.com\/wp-content\/uploads\/2026\/10\/\u7279\u70b9-768x278.jpg 768w, https:\/\/packagingleaktester.com\/wp-content\/uploads\/2026\/10\/\u7279\u70b9.jpg 1106w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"has-large-font-size wp-block-paragraph\"><strong>5\u3001Technical Specifications<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table is-style-regular\"><table class=\"has-accent-4-background-color has-background has-fixed-layout\"><tbody><tr><td><strong>Parameter<\/strong><\/td><td><strong>Specification<\/strong><\/td><\/tr><tr><td>Vacuum Setting Range<\/td><td>0 ~ -98KPa<\/td><\/tr><tr><td>Effective Size of Vacuum Chamber<\/td><td>\u03a6270 mm \u00d7 200 mm<\/td><\/tr><tr><td>Measuring Time<\/td><td>\u2264 9999 s<\/td><\/tr><tr><td>Time Accuracy<\/td><td>1 s<\/td><\/tr><tr><td>Pumping Rate<\/td><td>2 KPa\u00b7L\/s<\/td><\/tr><tr><td>Vacuum Pump Power<\/td><td>150 W<\/td><\/tr><tr><td>Main Unit Dimensions<\/td><td>300 mm \u00d7 240 mm \u00d7 120 mm<\/td><\/tr><tr><td>Operating Voltage<\/td><td>AC 220V, 50Hz<\/td><\/tr><tr><td>Total Weight<\/td><td>&nbsp;20 kg<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Leak Tester AIO-59D 1\u3001Product Overview Leak Tester AIO- [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-232","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/packagingleaktester.com\/index.php\/wp-json\/wp\/v2\/pages\/232","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/packagingleaktester.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/packagingleaktester.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/packagingleaktester.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/packagingleaktester.com\/index.php\/wp-json\/wp\/v2\/comments?post=232"}],"version-history":[{"count":2,"href":"https:\/\/packagingleaktester.com\/index.php\/wp-json\/wp\/v2\/pages\/232\/revisions"}],"predecessor-version":[{"id":234,"href":"https:\/\/packagingleaktester.com\/index.php\/wp-json\/wp\/v2\/pages\/232\/revisions\/234"}],"wp:attachment":[{"href":"https:\/\/packagingleaktester.com\/index.php\/wp-json\/wp\/v2\/media?parent=232"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}